Marine Survey Solution/Cable Locators

EML-3X Subsea EM Locator System

Three-axis EM subsea cable locator


  • Three-axis sensing — An orthogonal low-frequency probe records X, Y and Z magnetic-field components during cable crossings.
  • Passive and active modes — Survey energised power cables at 50/60 Hz, or use a shore-injected tracking signal for active detection.
  • Integrated survey positioning — The acquisition unit includes dual-antenna GNSS RTK for vessel position and true heading.
  • CableDetect workflow — Navigate, monitor waveforms, review candidate crossings, confirm cable positions and export survey results.
  • Condition-dependent depth estimates — Estimate burial depth where signal quality and crossing geometry support interpretation; review results against site conditions.
EML-3X Subsea EM Locator System

Cable Locators

Overview

EML-3X is a three-axis electromagnetic subsea cable locator for cable-position surveys in shallow coastal waters, harbours and navigation channels. It combines an orthogonal low-frequency EM probe, an acquisition and processing unit with dual-antenna GNSS RTK, and CableDetect software. The standard arrangement uses an over-the-side probe mount on a surface survey platform.

Passive mode detects the power-frequency magnetic field of an energised cable. Active mode uses a low-frequency signal injected at the shore end of a suitable cable circuit, with 33 Hz as a typical operating frequency. Survey lines cross the cable route to record magnetic-field features and identify cable positions.

CableDetect supports navigation, waveform monitoring, candidate review, manual confirmation and export. Cable positions and vessel tracks can be displayed on an electronic chart; CAD base maps and planned survey lines can be imported, and RAW records can be reprocessed offline. Burial-depth estimation depends on signal conditions and crossing geometry.

Applications

  • Cable route verification and maintenance surveys
  • Cable-position confirmation ahead of repair work
  • Active surveys of suitable de-energised or uncommissioned cables
  • Combined survey work with GeoScope sub-bottom profilers
EML-3X passive and active surface survey arrangement
Passive and active detection in a surface survey arrangement.
Redacted CableDetect field playback
Redacted CableDetect field playback. The displayed burial-depth estimate is a field example, not a rated detection-depth specification.

Specifications

Technical data

ParameterSpecification
Passive detection50 / 60 Hz power frequency
Active detection20–60 Hz; 33 Hz typical; shore-end signal injection
ProbeThree-axis orthogonal low-frequency EM probe
Probe weight20 kg
Standard mountingOver-the-side mount for surface operations
Positioning and headingBuilt-in dual-antenna GNSS RTK
External inputGNSS / INS / single-beam echo sounder via NMEA-0183
Acquisition unit dimensions210 × 155 × 85 mm
Acquisition unit weightApproximately 3 kg
Acquisition unit protectionIP67
Power19–24 V DC, 5 A
CommunicationGigabit Ethernet
Cable10 m standard; custom lengths available
Operating systemWindows 10 / 11, 64-bit
Coordinate systemsWGS84 / CGCS2000; UTM / Gauss-Krüger
Recommended survey speed4–6 kn, with 75–90° cable crossings
Burial-depth estimationSubject to signal conditions and crossing geometry; no fixed depth or accuracy rating specified
Download the full datasheet (PDF)

Discuss EML-3X Subsea EM Locator System for your project

Tell us about your vessel, water depth and deliverables, and our engineers will recommend a configuration.